490 2 × 2.3 A Blinds Controller

Blinds control

Mounting: DIN Rail

Number of channels: 2

Max load / channel (A): 2.3

Technical

  • Power supply rating: 197 VAC – 264 VAC (absolute) 48 Hz – 62 Hz
  • DALI power consumption (mA): 2
  • Control circuit protection: 6 A Type C MCB
  • Dimensions: 88 mm × 58 mm × 90 mm

Connections

  • DALI

Features

  • Two independent control channels
  • Volt free contacts for switching up/down or power / direction motors
  • “Break before Make” operation to prevent motor damage
  • Programmable “blind travel time”

492 16 A Power Relay Unit

Mounting: Independent use

Number of channels: 1

Max load / channel (A): 16

Technical

  • DALI power consumption (mA): 2
  • Dimensions: 118 mm × 40 mm × 21.2 mm

Connections

  • DALI

Features

  • Allows control of switched loads
  • For integration in luminaires or electrical cabinets
  • High-inrush specification relay

493 Signal Relay Unit

Mounting: Independent use

Number of channels: 1

Max load / channel (A): 0

Technical

  • DALI power consumption (mA): 2
  • Dimensions: 118 mm × 40 mm × 21.2 mm

Connections

  • DALI

Features

  • Allows interfacing with other building control and management systems
  • For integration in luminaires or electrical cabinets
  • Low power switching capability
  • Secure strain relief

494 4 × 10 A Relay Unit

Mounting: DIN Rail

Number of channels: 4

Max load / channel (A): 10

Technical

  • Power supply rating: 197 VAC – 264 VAC (absolute) 48 Hz – 62 Hz
  • DALI power consumption (mA): 2
  • Control circuit protection: 6 A Type C MCB
  • Dimensions: 88 mm × 90 mm × 58 mm

Connections

  • DALI

Features

  • 4 Individually programmable relays, normally open and volt-free
  • Relays are internally isolated permitting separate phases to be controlled in one unit
  • Manual override

498 8 × 16 A Relay Unit

Mounting: DIN Rail

Number of channels: 8

Max load / channel (A): 16

Universal power supply

Technical

  • Power supply rating: 85 VAC – 264 VAC (absolute) 45 Hz – 65 Hz
  • DALI power consumption (mA): 2
  • Control circuit protection: 6 A Type C MCB
  • Dimensions: 160 mm × 90 mm × 58 mm

Connections

  • DALI
  • S-DIM
  • DMX
  • Manual wired override input

Features

  • 8 Individually programmable relays, normally open and volt-free
  • High-inrush specification relays
  • Wired Override input
  • Manual configuration via LED display and push buttons

499 8 × 20 A Latching Relay Unit

Mounting: DIN Rail

Number of channels: 8

Max load / channel (A): 20

Universal power supply

Technical

  • Power supply rating: 85 VAC – 264 VAC (absolute) 45 Hz – 65 Hz
  • DALI power consumption (mA): 2
  • Control circuit protection: 6 A Type C MCB
  • Dimensions: 160 mm × 100 mm × 58 mm

Connections

  • DALI
  • S-DIM
  • DMX
  • Manual wired override input

Features

  • 8 Individually programmable relays, latching, single-pole
  • High-inrush specification relays
  • Manual control switch per relay
  • Staggerd switch-on to reduce inrush current